Higher quality reagents make Red Sea's Phosphate Pro Test kit more accurate than the previous model. A unique colorimetric comparator and clear, thorough instructions make using the test kit easy. Tests in the range of .0014 - 1.6 ppm. Accuracy of .014ppm. Includes reagents, analytic grade glass vials and colorimetric comparator. Part of the Reef Care Program. Helps your corals achieve the best health, vivid, electric coloration and rapid growth. Reef Care lines include: Algae Management, Reef Colors, Reef Foundation and Reef Energy. For the healthiest corals, use the entire Reef Care Program.

Click here for a Reef Care Algae Management Guide direct from Red Sea.

Click here for a Reef Care Information Guide direct from Red Sea.

Click here for a Reef Care FAQ direct from Red Sea.

Specifications

Internal ID
45342
Manufacturer
Red Sea
MPN
21425

Instructions

Directions for Phosphate Pro Test Kit

1. Using the syringe provided, place exactly 17 ml of the water to be tested into both of the glass vials.
2. Insert one of the vials (control vial) into the outer hole of the comparator.
3. Add 10 drops of Phosphate Pro Reagent A to the other vial (reaction vial), close the vial with the cap and shake for a few seconds.
4. Add 2 drops of Phosphate Pro Reagent B, close the vial with the cap and shake for a few seconds.
5. Remove the cap from the reaction vial and insert the vial into the center hole of the comparator.
6. Wait 6 minutes for the color in the reaction vial to stabilize.
7. When the end point of the test reaction has been reached look into both vials from above and rotate the color disc until the closest color match possible is achieved between the vials. Note: Turbidity or severe coloration of the water sample may distort the colors.
8. The phosphate level corresponding to the color selected is printed on the color disc as indicated by the pointer on the side of the comparator body. If necessary, estimate an intermediate value.
9. The color in the reaction vial will remain stable for 5 minutes. Do not relate to the color in the reaction vial after this time.

High Range: For levels of phosphate above 1 ppm dilute 2ml of the water to be tested with 15ml of RO water.